EN 54-16 / EN 54-4 / VDE 0833-4 / VDE 0828 / EN 50849 »EASY NETWORK« VOICE ALARM SYSTEM Key Features of the VARES-2000 System: + Manages up to 16 amplifiers per control centre (16,000 watts) + 2 simultaneous audio channels via an expandable matrix + Up to 1,500 loudspeaker lines + Up to 255 paging groups + Global and local network ports + Networkable (including with the VARES-1500 system)
VARES-2000

The flexible voice alarm system for maximum safety

In large buildings, every second counts when it comes to safety. The VARES-2000 is our powerful voice alarm system for complex projects – developed to provide clear instructions, prevent panic and guide people safely out of dangerous situations. It combines state-of-the-art technology, flexible expandability and maximum operational reliability – and is fully certified according to EN 54-16, EN 54-4, DIN VDE 0833-4 and DIN EN 50849.

Safety without compromise

The VARES-2000 is not just a technical system, but a reliable partner in an emergency. Thanks to its redundant network structure, it continues to operate even if parts of the system fail. The decentralised components ensure that each zone can be alerted independently – for maximum operational reliability.

The advantages of a VARES-2000 voice alarm system

  • Flexible use
    Ideal for large buildings with many alarm zones

  • Powerful
    Up to 1,440 speaker lines or 255 call groups

  • Efficient
    Integrated emergency power management for uninterrupted operation

  • Fail-safe reliability
    Decentralised architecture and redundant networking

  • Expandable
    Easy to combine with VARES-1500 & VARES LOOP

  • Total output
    Up to 240,000 W possible

  • Standards-compliant
    Certified according to EN 54-16, EN 54-4, DIN VDE 0833-4 and DIN EN 50849

Control-Center

The centrepiece – NCC-2000A

The NCC-2000A controls the entire voice alarm system, processes incoming signals according to clear priority logic and distributes them to up to 16 amplifiers via a modern AMP Link system. It supports both VARES LOOP technology and EOL monitoring, stores announcement texts and can manage up to two audio signals simultaneously.

Analogue audio inputs
AMP Link
Local network connections (L-Net)
Ethernet connections
Global network connections (G-Net)
Device ID
micro SD
USB
Calibration
Reset
GPO outputs
Relay outputs
EVAC / GPI inputs
24 V DC inputs (parallel connector)

NCC-2000 A - Control-Center

Speaker circuits expandable (with NLE-406 A) 6 to 1,440 individual circuits (grouped into max. 255 virtual call groups) Connections 1 x AMP connection (NDA-1000 A), 2 x Global Network, 3 x Local Network
Input contacts (monitored) 16 x inputs (expandable with NIM-116 A) Audio inputs 2 x BGM (analogue), balanced 0 dBu (expandable with NIM-116 A)
Output contacts 1 x alarm, 1 x fault contact (relay), 8 x mandatory call output (open collector) Voice memory 22 announcement texts of 5 min. each (17 freely available)
Frequency (Local Network) 50 - 20,000 Hz (-3 dB) Frequency (Global Network) 100 - 12,000 Hz (-3 dB)
Signal-to-noise ratio better than 90 dB Total harmonic distortion (THD) at 1 kHz ± 0.05%
Power supply 24 V DC / 300 mA Dimensions (W x H x D) 483 x 44.2 x 365 mm; 1 U
Weight approx. 2.5 kg
The control centre is the heart of the VARES-2000 system. It manages all functions of a voice alarm system, incoming information and audio signals. According to the requirements, it controls the network amplifiers, the A/B channels and the monitored line extensions. This also includes the management of audio streams coming from the network.

The VARES-2000 control centre processes the inputs according to its own signal priority table and distributes the audio signal via the digital AMP Link module, which manages two prioritised streams using dynamic assignment technology, to a maximum of 16 NDA-1000 A amplifiers per control centre.

The remotely controlled, monitored line extensions (NLE-406A) work directly with the NCC-2000 A. These units route the audio signals from the amplifier’s A/B channels to the required speaker areas or zones.

Two simultaneous audio signals are managed via an expandable switching matrix. This can range from a minimum of 6 speaker lines up to a maximum of 1,440 speaker lines, which can be grouped into a maximum of 255 virtual call zones.

The controller has monitored GPI and unmonitored GPO interfaces, as well as global and local network ports. The monitored AMP connection communicates with the NDA-1000 A amplifiers via the VARES-2000 data bus.

The VARES-2000 system uses the same configuration software as the VARES-1500 system, making it simple and straightforward to link both systems.

Features:

  • Audio matrix function with DSP
  • Up to 255 network nodes per system with peer-to-peer system redundancy (ring technology)
  • Mains voltage and battery monitoring
  • Supports loop technology and EOL (end-of-line)
  • Amplifier and microphone monitoring
  • Text module & digital voice memory
  • Priority channel with second and/or backup channel
  • 16 monitored or unmonitored inputs, freely configurable via software

NCC-2000 A

Lautsprecherkreise erweiterbar (mit NLE-406 A) 6 bis 1.440 Einzelkreise (gruppiert in max. 255 virtuelle Rufgruppen)
Anschlüsse 1x AMP-Verbindung (NDA-1000 A), 2x Global-Network, 3x Local-Network
Eingangskontakte (überwacht) 16x Eingänge (mit NIM-116 A erweiterbar)
Audioeingänge 2x BGM (analog) symmetrisch 0dBu (mit NIM-116 A erweiterbar)
Ausgangskontakte 1x Alarm-, 1x Fehlerkontakt (Relais), 8x Pflichtrufausgang (open collector)
Sprachspeicher 22 Durchsagetexte á 5 min. (17 frei)
Frequenz (Local-Network) 50 - 20.000 Hz (-3 dB)
Frequenz (Global-Network) 100 - 12.000 Hz (-3 dB)
Signal-Rauschabstand besser als 90 dB
Klirrfaktor (THD) bei 1 kHz ± 0,05%
Spannungsversorgung 24V DC / 300 mA
Abmessungen (BxHxT) 483 x 44,2 x 365 mm; 1 HE
Gewicht ca. 2,5 kg
Das Control-Center ist das Herzstück des VARES-2000 Systems. Es verwaltet alle Funktionen einer SAA, eingehende Informationen und Audiosignale. Entsprechend den Anforderungen steuert es die Netzwerk-Verstärker, die A/B-Kanäle und die überwachten Linienerweiterungen. Dies beinhaltet auch die Verwaltung von Audiostreams, die vom Netzwerk kommen.

Das VARES-2000 Control-Center verarbeitet die Eingänge entsprechend ihrer eigenen Signalprioritätstabelle und verteilt das Audiosignal über das digitale AMP-Link-Modul, das zwei priorisierte Streams über eine dynamische Zuweisungstechnik verwaltet, an maximal 16x Verstärker NDA-1000 A pro Control-Center.

Die ferngesteuerten, überwachten Linienerweiterungen (NLE-406A) arbeiteten direkt mit dem NCC-2000 A. Diese Einrichtungen leiten die Audiosignale von den A/B-Kanälen des Verstärkers in die erforderlichen Lautsprecherbereiche oder Zonen.

Zwei gleichzeitige Audiosignale werden über eine erweiterbare Schaltmatrix verwaltet. Dies kann von mindestens 6 Lautsprecherlinien bis zu einem Maximum von 1.440 Lautsprecherlinien reichen, die in maximal 255 virtuelle Rufzonen gruppiert werden können.

Der Controller besitzt überwachte GPI- und unüberwachte GPO-Schnittstellen, globale und lokale Netzwerkports. Die überwachte AMP-Verbindung kommuniziert über den VARES-2000 Datenbus mit den Verstärkern NDA-1000 A.

Das VARES-2000 System verwendet die selbe Konfigurationssoftware wie auch das VARES-1500 System, wodurch sich die Verknüpfung beider Systeme einfach und unkompliziert darstellt.

Merkmale:

  • Audio-Matrixfunktion mit DSP
  • Bis zu 255 Netzknoten pro System mit Peer-to-Peer-System-Redundant (Ringtechnologie)
  • Netzspannungs- und Batterieüberwachung
  • Unterstützt Loop-Technik und EOL (End-of-Line)
  • Verstärker- und Mikrofonüberwachung
  • Text-Modul & digitaler Sprachspeicher
  • Prioritätskanal mit zweitem und/oder Backup-Kanal
  • 16 überwachte oder unüberwachte Eingänge, frei konfigurierbar über Software
rcs-audio-sprachalarmierung-vares-systeme-saa-background

Digital Power Amplifier

The power behind it – NDA-1000A

The NDA-1000A digital network amplifier delivers 2 x 500 W RMS and is designed for maximum efficiency and fail-safe reliability. With integrated emergency power supply according to EN 54-4 and triple power supply redundancy, it is ready for use at all times – even in the event of a power failure.

Analogue audio inputs
AMP Link input
AMP Link output
AUX input
Audio outputs (100 V)
I/O interface fault / control / lamp
Local settings (DIP switches)
USB
24 V DC output (charging function)
Battery input
Power switch
IEC power connector

NDA-1000 A - Digital Power Amplifier

Output power 2 x 720/500 W (program/RMS) Output load 4 Ω min.; 20 Ω @ output power
Input sensitivity max. 775 mV (RMS) / 0 dBu balanced Output voltage 100 V
Frequency range 3 ~ 35,000 Hz (better than -3 dB) Signal-to-noise ratio better than 90 dB
Total harmonic distortion (THD) at 1 kHz better than 0.1% Crosstalk (20 Hz – 20 kHz) < -100 dB
Power consumption max. 1350 W Inrush current max. 6 A @ 230 V AC
DC current consumption max. 45 A @ 24 V DC Idle mode 24 W (active) / 0.9 W (standby)
Idle current consumption (DC) 1 A (active) / 34 mA (standby) Efficiency 89% @ 230 V AC / 93% @ 24 V DC
DC output (external devices) max. 60 W / 2 A Charging voltage max. 27.9 V DC
Charging current max. 4 A Dimensions (W x H x D) 483 x 88.5 x 350 mm; 2 U
Weight approx. 16.5 kg
The network digital power amplifier provides powerful audio amplification according to EN 54-16 and an integrated emergency power supply according to EN 54-4.

Depending on the configuration, the power amplifier delivers 2 x 500 W output power and is housed in a 19″ rack housing with 2 U. It differs from conventional power amplifiers through its fully digital system architecture and its three redundant power supplies.

Several NDA-1000 A amplifiers can be connected to one battery set. The active charger charges the battery set, which provides the backup power supply. In addition, an external 24 V connection is available for supplying additional modules.

Features:

  • Digital power amplifier with integrated emergency power supply. The scalable battery charger features a temperature sensor and is certified according to EN 54-4.
  • Indicators: Power; Link; Battery; Charger, fault message CH A SIG / CLIP; CH B SIG / CLIP
  • The following connections are available: 2 x global network connection (AmpLink), 2 x 500 W power outputs
  • Battery set connection and 24 V DC output for external components.
  • The amplifier has two BGM inputs for stand-alone operation and one AUX input (mono, balanced) or 2-channel stereo operation (unbalanced), each (analogue) 0 dBu.
  • Mains fault monitoring with switchover to emergency power operation.
  • Monitoring of battery faults (with internal resistance measurement).
  • Monitoring of the power outputs.

NDA-1000 A

Ausgangsleistung 2x 720/500 W (Programm/RMS)
Ausgangslast 4Ω min.; 20Ω @Ausgangsleistung
Eingangsempfindlichkeit max. 775 mV (RMS) / 0dBu symmetrisch
Ausgangsspannung 100 V
Frequenzbereich 3 ~ 35.000 Hz (besser -3 dB)
Signal-Rauschabstand besser als 90 dB
Klirrfaktor (THD) bei 1 kHz besser als 0,1%
Übersprechen (20 Hz – 20 kHz) < -100 dB
Leistungsaufnahme max. 1350 W
Einschaltstrom max. 6A @ 230V AC
DC Stromaufnahme max. 45A @ 24V DC
Leerlauf 24 W (aktiv) / 0.9 W (standby)
Leerlaufstromaufnahme (DC) 1 A (aktiv) / 34 mA (standby)
Wirkungsgrad 89% @ 230V AC / 93% @ 24V DC
DC Ausgang (ext. Geräte) max. 60W / 2A
Ladespannung max. 27.9V DC
Ladestrom max. 4A
Abmessungen (BxHxT) 483 x 88,5 x 350 mm; 2 HE
Gewicht ca. 16,5 kg
Der Network Digital Power Amplifier bietet eine leistungsstarke Audioverstärkung nach EN 54-16 und eine integrierte Notstromversorgung nach EN 54-4.

Der Leistungsverstärker liefert konfigurationsabhängig 2x 500 W Ausgangsleistung und ist in einem 19˝-Rackgehäuse mit 2 HE untergebracht. Er unterscheidet sich von herkömmlichen Leistungsverstärkern durch seine volldigitale Systemarchitektur und seine drei redundant ausgelegten Netzteile.

Es können mehrere NDA-1000 A Verstärker an einem Akkusatz zusammen geschaltet werden. Das aktive Ladegerät lädt den Akkusatz, der die Backup Spannungsversorgung bildet. Zusätzlich steht auch ein externer 24V-Anschluss zur Versorgung von Zusatzbaugruppen zur Verfügung.

Merkmale:

  • Digitaler Leistungsverstärker mit integrierter Notstromversorgung. Das skalierbare Batterieladegerät verfügt über einen Temperatursensor und ist gemäß EN54-4 zertifiziert.
  • Anzeigen: Power; Link; Battery; Charger, Fehlermeldung CH A SIG / CLIP; CH B SIG / CLIP
  • Folgende Anschlüsse stehen zur Verfügung: 2x Globaler Netzwerkanschluss (AmpLink), 2x 500 W Leistungsausgänge
  • Akkusatz-Anschluß und 24 V DC Ausgang für externe Komponenten.
  • Der Verstärker verfügt über zwei BGM-Eingänge für den Stand-Alone Betrieb und einen AUX-Eingang (Mono, symmetrisch) oder 2-Kanalbetrieb Stereo (unsymmetrisch), jeweils (analog) 0dBu.
  • Netzfehlerüberwachung mit Umschaltung auf Notstrombetrieb.
  • Überwachung von Akkufehlern (mit Innenwiderstands-Messung).
  • Überwachung der Leistungsausgänge.
rcs-audio-sprachalarmierung-vares-2000-slider-hintergrund
rcs-audio-sprachalarmierung-vares-2000-youtube-video-darkrcs-audio-sprachalarmierung-vares-2000-youtube-video-red

System overview

Train Stations
Shopping Centres
Hotels

Hospitals

Stadiums

Areas of application

The VARES-2000 voice alarm system is ideal for large-scale or complex buildings with high safety requirements, such as:

  • Airports and train stations

  • Stadiums, arenas and event halls

  • Large hotels and resorts

  • Hospitals and public facilities

  • Shopping centres and office complexes

At different locations

rcs-audio-sprachalarmierung-vares-2000-planer-ingenieur-background

For specialist planners and engineering firms

COST SAVINGS

The practical combination of voice alarm controller, external line modules and system power amplifiers with integrated emergency power management makes it easy to set up any system.

FLEXIBILITY

Digital networking of the VARES-2000 and VARES-1500 allows both systems to be easily expanded or combined, even in a decentralised setup. The VARES-2000 system monitors the speaker lines via impedance monitoring (EOL) or supports VARES LOOP technology.

SAFETY

Together with the VARES-1500, the VARES-2000 system offers comprehensive safety. Even in the event of faults within the redundant network, the systems distributed throughout the building continue to operate independently thanks to the decentralised alarm notification concept, ensuring that area-specific alarm notification remains available.

Maximum safety for complex projects

With the VARES-2000, you rely on a voice alarm system that operates reliably even in critical situations. It has been designed to remain operational even in the event of faults or network failures. This means you can be sure that your evacuation and alarm notification strategy always works.